The short answer
When an automatic gate won't open or close, the cause is usually simple: no power or a tripped breaker, a dead backup battery, a dead remote battery, blocked or dirty photo eyes, or an operator left in manual release. Check those five first. If the gate beeps, stops halfway or the motor hums without moving, the problem is more likely an obstruction alarm, the gate itself, or the control board.
Safety first
An automatic gate is heavy and can move without warning. Turn off power at the breaker before you touch the operator, the arm or the track. Keep kids and pets away, never reach through a moving gate, and never bypass the photo eyes or safety edges to make the gate close.
A gate that won't move is one of the most common calls we get, from Seattle and Bellevue to Tacoma and Everett. Most problems can be narrowed down in a few minutes. This guide walks through 12 causes in the order we check them, with what you can safely try yourself and when it's time to call for gate repair.
Start with these 5 quick checks
Power: is the breaker on and the GFCI outlet reset? Are there lights on the control board?
Remote: does the keypad or a second remote work? If so, change the remote's battery.
Photo eyes: is anything in the gate's path, and are the photo eye lenses clean and facing each other?
Manual release: was the operator released by hand and never re-engaged?
Sounds: is the operator beeping, alarming or humming? Note the pattern before you reset anything.
12 reasons an automatic gate won't open or close
1. No power to the operator
A tripped breaker, a tripped GFCI outlet or a storm outage cuts power to the gate. If the control board has no lights, start here. Reset the breaker once. If it trips again, stop and call us, because something is shorting.
2. A dead or weak backup battery
Many gate operators run on a backup battery when power is out. A worn-out battery can leave the gate stuck after an outage. On a LiftMaster LA400UL, when AC power is off and the battery gets critically low, the gate stops at a limit, and a setting decides whether it stays open or closed. LiftMaster recommends replacing gate operator batteries every 3 years, and batteries work poorly in extreme cold.
3. The remote's battery is dead or the remote lost its code
If the keypad works but the remote doesn't, replace the remote's battery first. If it still won't work, the remote may need to be reprogrammed. See how to program a LiftMaster gate opener.

A LiftMaster slide gate operator and control box. Lights on the control board tell you the operator has power.
4. Blocked, dirty or misaligned photo eyes
Photo eyes stop a gate from closing on a car or a person. Leaves, snow, spider webs or a bumped sensor can make the gate refuse to close or reverse right away. Clean the lenses with a soft cloth and check that both sensors face each other squarely.
5. An obstruction alarm
If the gate hits something twice in a row, the operator may lock out and sound an alarm. On a LiftMaster RSL12UL slide operator, two obstructions in a row set off an alarm for up to 5 minutes, and the operator needs a reset before it will run again. Find and clear the cause first. Resetting without fixing it just trips the alarm again.
6. The operator is still in manual release
After a power outage, someone may have released the gate by hand. If the motor runs but the gate doesn't move, the release is probably still disengaged. Our guide on opening an electric gate in a power outage shows how to release and re-engage common LiftMaster operators.
7. Debris, ice or damage on a sliding gate's track
Rocks, packed gravel, ice and broken wheels make a slider bind and trip its obstruction sensing. Clear the track with the power off, and look for a wheel that has jumped the rail or a bent track.
8. A sagging gate or worn hinges
A swing gate that drags on the driveway or binds at the hinges makes the operator work too hard. The operator reads that as an obstruction and stops. Sagging usually means worn hinges or a post that has moved, which is a repair job.

A technician checking a commercial gate operator's control board on site.
9. Limits out of adjustment
Limits tell the operator where open and closed are. If they drift, the gate may stop short, overrun or reverse. Limit settings vary by model, so follow your operator's manual or have a technician reset them.
10. A vehicle loop or exit wand holding the gate open
If the gate opens but never closes, a vehicle detector may think a car is still there. A damaged loop wire, a parked car or metal near an exit wand can hold the gate open.
11. A timer, hold-open or access setting
A timer-to-close that is turned off, a keypad hold-open code or a fire access device can keep the gate open on purpose. Check whether anyone changed a setting recently.
12. A failed control board, motor or gearbox
Water damage, a lightning surge or plain old age can take out the board or the motor. A humming motor that doesn't turn, a burnt smell or a dead board with good power all point here. This needs a technician. Read how long gate openers last if you're deciding between repair and replacement.
Symptom checker
What the gate does
Most likely causes
Nothing at all, no lights
No power, tripped breaker or GFCI, dead battery
Keypad works, remote doesn't
Remote battery, remote lost its code, range
Opens but won't close
Photo eyes, vehicle loop or exit wand, timer setting
Starts, then stops and reverses
Obstruction, sagging gate, debris on the track, limits
Beeps or alarms
Obstruction alarm, low battery
Motor runs, gate doesn't move
Manual release disengaged, broken arm or chain
Motor hums, nothing turns
Failed motor, gearbox or capacitor
General guidance for common residential gate operators. Your model's manual has the exact error codes.
When to call a gate technician
Call a pro when a breaker keeps tripping, the motor hums without moving, the gate is bent or off its track, or the operator alarms again right after a reset. Also call if you're not sure, because a wrong fix on a heavy gate can hurt someone. We repair LiftMaster, Chamberlain, DoorKing, Viking, Elite and CellGate systems across Washington and Oregon.

An Evergreen technician servicing a black steel swing gate at a customer's driveway.
How to keep it from happening again
Replace the backup battery about every 3 years.
Clean the photo eyes and clear the track every month or two.
Keep plants trimmed back from the gate and sensors.
Book a yearly service. See our gate maintenance checklist and maintenance plans.
Evergreen Electric Gates at a glance
Who wrote this guide
We design, build, install and repair automatic gates across Washington and Oregon. Facts about us, in one place:
In business since 2008, with our fabrication shop at 21702 84th Ave S #2, Kent, WA 98032
We build our own steel gates (galvanized, then powder coated) and back them with a 10-year warranty
We install LiftMaster gate operators and service LiftMaster, Chamberlain, DoorKing, Viking, Elite and CellGate systems
We work in King, Snohomish, Pierce and Kitsap counties, plus Vancouver, WA and Portland, OR
Quotes are free and there is no service-call fee
Frequently Asked Questions
Why won't my automatic gate close?
The most common causes are blocked or dirty photo eyes, a vehicle loop or exit wand that thinks a car is there, or a timer-to-close that is turned off. Clear the gate's path, clean both photo eye lenses and check that they face each other.
Why does my gate open but not close all the way?
It may be reading an obstruction from a sagging gate, debris on the track or limits that have drifted. Check for drag and debris with the power off. If it keeps happening, the limits or hinges need adjusting.
Why is my gate opener beeping?
Beeping usually means an obstruction alarm or a low battery. Clear anything in the gate's path, then reset the operator. If it beeps again right away, the cause hasn't been fixed.
Can cold weather stop my gate from working?
Yes. Backup batteries perform poorly in extreme cold, ice can jam a sliding gate's track, and snow can block photo eyes. Keep the track and sensors clear in winter.
Why does my remote not work but my keypad does?
The remote's battery is likely dead, or the remote has lost its code. Change the battery, then reprogram it with the learn button if needed.
Is it safe to fix my own gate?
Simple checks like breakers, remote batteries and cleaning photo eyes are fine. Turn off power before touching the operator or track, and leave motors, boards, springs and hinges to a technician.
Not sure where to start? Try our free 2-minute gate self-checkup. It walks you through the symptoms and tells you what to try next.

Gate still stuck? We can help
Tell us what the gate is doing and we'll get a technician out. We repair all major brands across Washington and Oregon, with no service-call fee.
Written by the Evergreen Electric Gates team in Kent, WA. Model details checked against LiftMaster installation manuals, October 2026.