The short answer
To open an electric gate in a power outage, turn off the gate's breaker, wait until the gate is fully stopped, then use the operator's manual release, usually a key and lever, a release handle or a crank. Then move the gate by hand. Many gates with a backup battery keep working for a while first. When power returns, re-engage the release so the gate locks and runs again.
Before you touch the gate
Only use the manual release when the gate is not moving. Turn off power at the breaker first, so the gate can't start when power comes back. A released gate can swing or roll on its own on a slope or in wind, so keep people and pets clear and move it slowly.
Puget Sound storms knock out power every winter, and a gate that won't open can trap you in or out. The good news: every UL 325 automatic gate operator has a way to release it by hand. Here's how to do it on the LiftMaster operators we see most, based on LiftMaster's own installation manuals.
Does my gate have a battery backup?
Many modern gate operators, including most LiftMaster DC models, have a backup battery that keeps the gate running for a while during an outage. When the battery runs low, the gate may stop working, or may stop in a set position. On a LiftMaster LA400UL, when the power is out and the battery is critically low, the gate stays at its open or closed limit. A setting on the board decides which one: set to open, the gate opens and stays open; set to close, it stays closed.

The arm of a LiftMaster swing gate operator. Swing operators like this release with a key and lever.
How to release common LiftMaster operators
LiftMaster LA400UL (swing arm)
Turn off power to the operator.
Insert the release key and turn it 180° counter-clockwise.
Turn the release lever 180° counter-clockwise. The arm is now free.
Move the gate by hand.
To lock it again, reverse the steps and put the key somewhere safe.
After a disconnect or a power loss, the LA400UL may run slowly until it finishes one full open and close cycle. That's normal.
LiftMaster RSW12UL (residential swing)
Set the reset switch to RESET/DISCONNECT, then use the release handle on the arm to free the gate. On a dual gate, do it on both operators. Push the handle back down to resume automatic operation.
LiftMaster RSL12UL (residential slide)
The reset switch is on the front of the operator. Press it to the off position ("O") and the gate can be slid by hand. On a dual slide setup, do this on both operators. Put the switch back to "I" to resume normal operation.

A LiftMaster slide gate operator on its concrete pad. Slide operators release with a switch or a crank, depending on the model.
LiftMaster SL3000UL (commercial slide)
Turn off the operator's dedicated breaker, then turn the drive by hand with the crank tool. A 5/16-inch hex bit in a drill also works. Some units have an optional T-handle chain release.
Other brands
DoorKing, Viking, Elite and others work the same way in principle: power off, release, move by hand, re-engage. The release is usually under the cover or on the arm, and the steps are in the manual. If you can't find yours, call us and we'll talk you through it.
What to do when the power comes back
Make sure the gate is in its closed or open position, not halfway.
Re-engage the release so the drive is locked again.
Turn the breaker back on.
Run the gate through one full cycle with everyone clear.
If it won't run, see why an automatic gate won't open or close.
Get ready before the next outage
Know where the release key or tool is. Keep it in the house, not in the operator box.
Replace the backup battery about every 3 years. LiftMaster recommends it, and old batteries quit fast in the cold.
Decide how the gate should behave when the battery runs out. Open is easier for deliveries and fire access; closed is more secure.
Look at solar power if the gate is far from the house. See solar gates.
Book a yearly service so the battery and release get checked. See maintenance plans.

A cedar and steel sliding gate after a snowfall. Winter storms are when most of our power outage calls come in.
Evergreen Electric Gates at a glance
Who wrote this guide
We design, build, install and repair automatic gates across Washington and Oregon. Facts about us, in one place:
In business since 2008, with our fabrication shop at 21702 84th Ave S #2, Kent, WA 98032
We build our own steel gates (galvanized, then powder coated) and back them with a 10-year warranty
We install LiftMaster gate operators and service LiftMaster, Chamberlain, DoorKing, Viking, Elite and CellGate systems
We work in King, Snohomish, Pierce and Kitsap counties, plus Vancouver, WA and Portland, OR
Quotes are free and there is no service-call fee
Frequently Asked Questions
Can I open my electric gate without power?
Yes. Every automatic gate operator has a manual release. Turn off the breaker, wait for the gate to stop, use the release, and move the gate by hand.
Will my gate open by itself when the power goes out?
Usually not. Most gates stay where they are. Some operators with a backup battery can be set to open, or to stay closed, when the battery runs out.
How long does a gate's backup battery last in an outage?
It depends on the battery's age, the temperature and how often the gate cycles. A new battery handles more cycles than an old one, and cold weather shortens it. Replace batteries about every 3 years.
What if I lost the manual release key?
Don't force the cover. Call us or a LiftMaster dealer for a replacement key, and we can open the gate for you in the meantime.
Should I leave my gate open during a storm?
If you expect a long outage, releasing the gate and leaving it open can make it easier for you, deliveries and emergency crews to get in. Re-engage it once power is back.
Why is my gate slow after the power came back?
On some LiftMaster models, the operator runs slowly until it completes one full cycle after a power loss. If it stays slow, have the battery and operator checked.
Gate acting strange after an outage? Try our free 2-minute gate self-checkup or see our gate repair service.

Stuck after a storm?
Call us and we'll walk you through the release, or send a technician to get the gate working again. We serve Washington and Oregon, with no service-call fee.
Written by the Evergreen Electric Gates team in Kent, WA. Steps checked against LiftMaster installation manuals (LA400UL, RSW12UL, RSL12UL, SL3000UL), October 2026.